HIGHCVSS v3.1 8.1Vulnerability

CVE-2026-54161

Network UPS Tools is a collection of programs which provide a common interface for monitoring and administering UPS, PDU and SCD hardware. From 2.8.3 to 2.8.5, upsmon in clients/upsmon.c inserts the server-supplied ups.alarm value into shell commands executed by notify(), async_notify(), and wall(). When a monitored device reports an ALARM state and an operator has configured NOTIFYCMD with EXEC in NOTIFYFLAG ALARM, shell metacharacters in the alarm text are evaluated on POSIX or Windows and can execute arbitrary operating-system commands as the upsmon account, which is commonly root. An attacker can control the value through a malicious or compromised upsd, a man-in-the-middle on a plaintext upsd to upsmon connection, or a compromised UPS device whose driver supplies the alarm upstream of upsd; TLS between upsd and upsmon does not mitigate the compromised-device path. This vulnerability is fixed in 2.8.6.

Properties

Severity
HIGH
Nvd fetched at
2026-11-03T21:24:30.963596+00:00
Cvss severity
HIGH
Cvss score
8.1
Retrieved at
2026-11-03T21:25:36+00:00
Score
8.1
Cvss version
3.1
Last source
NVD
Cve id
CVE-2026-54161
Cvss vector
CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
First seen by Signal
2026-11-03T21:21:12+00:00
Vector
CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
Published at
2026-11-03T20:18:14.243
Last modified
2026-11-03T20:18:14.243

Related Entities (1)